Mon–Fri 8:00–17:00

Steel systems · fire safety

Fire and smoke
control without a compromise on appearance.

From doors and entrance zones to roof glazing. The required fire-resistance class is achieved by selecting the right components and infill elements. They are internal and do not affect the external appearance.

Janisol 2 EI30
EI30

Janisol 2 EI30

Fire doors and partitions. Steel allows slim profiles with a secure construction.
  • Fire resistance EI30 (EN 1634-1, DIN 4102-5)
  • Smoke control DIN 18095 / EN 1634-3 · emergency exits EN 1125 / EN 179
  • Door height up to 2.5–3 m · burglar resistance RC1–3 · also anti-finger-trap
View system
Janisol 2 EI30 70 mm
70 mm

Janisol 2 EI30 70 mm

Installation depth 70 mm — lets Janisol C4 EI60 (even EI90) partitions be combined with Janisol 2 EI30.
  • Fire resistance EI30/EI60/EI90 · installation depth 70 mm
  • Emergency exits EN 179/1125
  • Thermal transmittance from 1.5 W/m²K · burglar resistance up to RC3
View system
Janisol C4 EI60 / EI90
EI60 / EI90

Janisol C4 EI60 / EI90

An innovative fire infill — classes up to EI90 with an element thickness of only 70 mm.
  • EI60 / EI90 tested to EN 1634-1 and DIN 4102-5
  • Smoke control DIN 18095 / EN 1634-3
  • Door height up to 2.50 m · Rw up to 43 dB
View system
Jansen Economy 50 E30–EW60
Economy

Jansen Economy 50 E30–EW60

For partitions up to E120. Appearance identical to Economy 60, Janisol 2 and Janisol C4.
  • Door height up to 3.8 m
  • Fire resistance E30/EW30/E60/EW60; up to E120 for fixed glazing
  • Combines with Economy 50 RS smoke protection
View system
Jansen Economy 60 E30–EW60
Economy

Jansen Economy 60 E30–EW60

Fire doors and display units up to E90. Profiles accept smoke-protection components to DIN 18095.
  • Single or double leaf; partitions; integrated closers
  • Door height up to 3.8 m
  • Smoke control DIN 18095 / EN 1634-3
View system
Janisol 2 EI30 fire sliding doors
Sliding

Janisol 2 EI30 fire sliding doors

Slim frame profiles for shopping centres, stadiums and office buildings. With or without an emergency exit.
  • Without an emergency exit: up to 2800 × 2500 mm
  • With an emergency exit: up to 2400 × 2500 mm
  • Installed in EI30, EI60 and EI90 partitions · elements up to 4040 × 5900 mm
View system
Jansen Economy 50 RS
Smoke

Jansen Economy 50 RS

Smoke-control doors and partitions for large, heavy leaves. Stainless steel 1.4404 available.
  • Smoke control DIN 18095 / EN 1634-3
  • Single or double leaf; partitions; integrated closers
  • Can be combined with fire resistance, or used without it
View system
Jansen Economy 60 RS
Smoke

Jansen Economy 60 RS

Smoke-control doors to DIN 18095.
  • Single or double leaf; integrated closers
  • Smoke control DIN 18095 / EN 1634-3
  • Burglar resistance up to RC3
View system
Janisol 1 fire windows
Windows

Janisol 1 fire windows

JANISOL 1 fire-rated 330/E45 windows for rooms with fire-safety requirements.
  • Window sash up to 1265 × 2300 mm · installation depth 60 mm
  • Fire resistance E45/EW45 · tested to EN 14351-1 and EN 16034
  • Rw up to 43 dB · glass up to 40 mm
View system
Janisol 2 Anti-finger EI30
EI30

Janisol 2 Anti-finger EI30

EI30 fire doors with rounded frame sections that reduce the risk of injury at the hinge edge.
  • Fire resistance EI30
  • Rounded frame sections at the hinge edge
View system
VISS Fire EI30 façade
EI30

VISS Fire EI30 façade

A fire-resistant façade. Glass sizes up to 2300 mm wide and 4600 mm high.
  • Infill 15–70 mm · installation depths 50–280 mm
  • Glass sizes up to 2300 × 4600 mm
  • Tested to EN 1364-1 and EN 1364-2 · classified to EN 13501-2
View system

We manufacture to your project.

Send a drawing or dimensions. We will match a Jansen or Schüco system and prepare a quote — for windows, doors, CNC parts or metal products.

Get directions

Choose a navigation app to get directions to the workshop.

Hero video: Coverr, commercial-use glass facade footage.